4.6

CiteScore

2.2

Impact Factor
  • ISSN 1674-8301
  • CN 32-1810/R
Shengnai Zheng, Qingqiang Yao, Li Cheng, Yan Xu, Peng Yuan, Dongsheng Zhang, Xiangwen Liao, Liming Wang. The effects of a new shape-memory alloy interspinous process device on the distribution of intervertebral disc pressures in vitro[J]. The Journal of Biomedical Research, 2010, 24(2): 115-123.
Citation: Shengnai Zheng, Qingqiang Yao, Li Cheng, Yan Xu, Peng Yuan, Dongsheng Zhang, Xiangwen Liao, Liming Wang. The effects of a new shape-memory alloy interspinous process device on the distribution of intervertebral disc pressures in vitro[J]. The Journal of Biomedical Research, 2010, 24(2): 115-123.

The effects of a new shape-memory alloy interspinous process device on the distribution of intervertebral disc pressures in vitro

Funds: 

This study was supported by the Medical Key Technology Development Program, Nanjing Health Bureau (ZKK08010).

More Information
  • Received Date: September 02, 2009
  • This study was designed to measure the pressure distribution of the intervertebral disc under different degrees of distraction of the interspinous process, because of a suspicion that the degree of distraction of the spinous process may have a close relationship with the disc load share. Six human cadaver lumbar spine L2-L5 segments were loaded in flexion, neutral position, and extension. The L3-L4 disc load was measured at each position using pressure measuring films. Shape-memory interspinous process implants (SMID) with different spacer heights, ranging in size from 10 to 20 mm at 2 mm increments, were used. It was found that a SMID with a spacer height equal to the distance of the interspinous process in the neutral position can share the biomechanical disc load without a significant change of load in the anterior annulus. An interspinous process stabilizing device (IPD) would not be appropriate to use in those cases with serious spinal stenosis because the over-distraction of the interspinous process by the SMID would lead to overloading the anterior annulus which is a recognized cause of disc degeneration.
  • Related Articles

    [1]Izzatullo Ziyoyiddin o`g`li Abdullaev, Ulugbek Gapparjanovich Gayibov, Sirojiddin Zoirovich Omonturdiev, Sobirova Fotima Azamjonovna, Sabina Narimanovna Gayibova, Takhir Fatikhovich Aripov. Molecular pathways in cardiovascular disease under hypoxia: Mechanisms, biomarkers, and therapeutic targets[J]. The Journal of Biomedical Research. DOI: 10.7555/JBR.38.20240387
    [2]Tianle Jin, Maoxing Fei, Shiqiao Luo, Handong Wang. Piezo1 as a potential player in intracranial hemorrhage: From perspectives on biomechanics and hematoma metabolism[J]. The Journal of Biomedical Research, 2024, 38(5): 436-447. DOI: 10.7555/JBR.37.20230241
    [3]Shen Qin, Li Jianqing, Cui Chang, Wang Xingyao, Gao Hongxiang, Liu Chengyu, Chen Minglong. A wearable real-time telemonitoring electrocardiogram device compared with traditional Holter monitoring[J]. The Journal of Biomedical Research, 2021, 35(3): 238-246. DOI: 10.7555/JBR.34.20200074
    [4]Boubchir Larbi. Editorial commentary on special issue of Advances in EEG Signal Processing and Machine Learning for Epileptic Seizure Detection and Prediction[J]. The Journal of Biomedical Research, 2020, 34(3): 149-150. DOI: 10.7555/JBR.34.20200700
    [5]Huan Liu, Shijiang Zhang, Yongfeng Shao, Xiaohu Lu, Weidong Gu, Buqing Ni, Qun Gu, Junjie Du. Biomechanical characterization of a novel ring connector for sutureless aortic anastomosis[J]. The Journal of Biomedical Research, 2018, 32(6): 454-460. DOI: 10.7555/JBR.31.20170011
    [6]Minbo Zang, Qiao Zhou, Yunfei Zhu, Mingxi Liu, Zuomin Zhou. Effects of chemotherapeutic agent bendamustine for nonhodgkin lymphoma on spermatogenesis in mice[J]. The Journal of Biomedical Research, 2018, 32(6): 442-453. DOI: 10.7555/JBR.31.20170023
    [7]Zhifeng Sun, Kaixiang Yang, Hongtao Chen, Tao Sui, Lei Yang, Dawei Ge, Jian Tang, Xiaojian Cao. A novel entry point for pedicle screw placement in the thoracic spine[J]. The Journal of Biomedical Research, 2018, 32(2): 123-129. DOI: 10.7555/JBR.31.20160037
    [8]Wei Zhu, Wenzhu Fang, Shanshan Zhan, Yuxuan Zhou, Qing Gao, Xingya Gao. Volume conduction energy transfer for implantable devices[J]. The Journal of Biomedical Research, 2013, 27(6): 509-514. DOI: 10.7555/JBR.27.20130090
    [9]Gang Niu, Xuewen Yu, Jian Yang, Rong Wang, Shaojuan Zhang, Youmin Guo. Apparent diffusion coefficient in normal and abnormal pattern of intervertebral lumbar discs: initial experience[J]. The Journal of Biomedical Research, 2011, 25(3): 197-203. DOI: 10.1016/S1674-8301(11)60026-2
    [10]Sundeep?S.?Tumber, Hong?Liu. Epidural abscess after multiple lumbar punctures for labour epidural catheter placement[J]. The Journal of Biomedical Research, 2010, 24(4): 332-335. DOI: 10.1016/S1674-8301(10)60046-2

Catalog

    Article Metrics

    Article views (2418) PDF downloads (1043) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return