4.6

CiteScore

2.2

Impact Factor
  • ISSN 1674-8301
  • CN 32-1810/R
Juming Li, Hong Zhao, Hao Xie, Lipeng Yu, Jifu Wei, Min Zong, Feng Chen, Ziqiang Zhu, Ning Zhang, Xiaojian Cao. A new free-hand pedicle screw placement technique with reference to the supraspinal ligament[J]. The Journal of Biomedical Research, 2014, 28(1): 64-70. DOI: 10.7555/JBR.27.20130051
Citation: Juming Li, Hong Zhao, Hao Xie, Lipeng Yu, Jifu Wei, Min Zong, Feng Chen, Ziqiang Zhu, Ning Zhang, Xiaojian Cao. A new free-hand pedicle screw placement technique with reference to the supraspinal ligament[J]. The Journal of Biomedical Research, 2014, 28(1): 64-70. DOI: 10.7555/JBR.27.20130051

A new free-hand pedicle screw placement technique with reference to the supraspinal ligament

More Information
  • Received Date: April 15, 2013
  • We sought to compare the safety and accuracy of a new free-hand pedicle screw placement technique to that of the conventional technique. One hundred fifty-three consecutive adult patients with simple fracture in the tho-racic or/and lumbar spine were alternately assigned to either the new free-hand or the conventional group. In the new free-hand technique group, preoperative computerized tomography (CT) images were used to calculate the targeted medial-lateral angle of each pedicle trajectory and the pedicle screw was inserted perpendicular to the corresponding supraspinal ligament. In the conventional technique group, the medial-lateral and cranial-caudal angle of each pedicle trajectory was determined by intraoperatively under fluoroscopic guidance. The accuracy rate of pedicle screw placement, the time of intraoperative fluoroscopy, the operating time and the amount of blood loss during operation were respectively compared. All screws were analyzed by using intraoperative ra-diographs, intraoperative triggered electromyography (EMG) monitoring data, postoperative CT data and clinical outcomes. The accuracy rate of pedicle screw placement in the new free-hand technique group and the conven-tional technique group was 96.3% and 94.2% (P < 0.05), respectively. The intraoperative fluoroscopy time of the new technique group was less than that of the conventional technique group (5.37 seconds vs. 8.79 seconds, P < 0.05). However, there was no statistical difference in the operating time and the amount of blood loss during op-eration (P > 0.05). Pedicle screw placement with the free-hand technique which keeps the screw perpendicular to the supraspinal ligament is an accurate, reliable and safe technique to treat simple fracture in the thoracic or lum-bar spine.
  • Related Articles

    [1]Shu Wei, Zhang Yanman, Zhang Chen, You Qiang, Zhou Hong, Wen Shuang. Triclosan inhibits the activation of human periodontal ligament fibroblasts induced by lipopolysaccharide from Porphyromonas gingivalis[J]. The Journal of Biomedical Research, 2021, 35(3): 206-215. DOI: 10.7555/JBR.34.20200026
    [2]Kim Byung Cheol, Song Jae-In, So Kyoung-Ha, Hyun Sang-Hwan. Effects of lysophosphatidic acid on human periodontal ligament stem cells from teeth extracted from dental patients[J]. The Journal of Biomedical Research, 2019, 33(2): 122-130. DOI: 10.7555/JBR.32.20170123
    [3]Zhifeng Sun, Kaixiang Yang, Hongtao Chen, Tao Sui, Lei Yang, Dawei Ge, Jian Tang, Xiaojian Cao. A novel entry point for pedicle screw placement in the thoracic spine[J]. The Journal of Biomedical Research, 2018, 32(2): 123-129. DOI: 10.7555/JBR.31.20160037
    [4]Arjang Ahmadpour, Amir Goodarzi, Darrin J. Lee, Ripul R. Panchal, Kee D. Kim. Cervical spine fractures in osteopetrosis: a case report and review of the literature[J]. The Journal of Biomedical Research, 2018, 32(1): 68-76. DOI: 10.7555/JBR.32.20170055
    [5]Haijun Li, Lei Yang, Hao Xie, Lipeng Yu, Haifeng Wei, Xiaojian Cao. Surgical outcomes of mini-open Wiltse approach and conventional open approach in patients with single-segment thoracolumbar fractures without neurologic injury[J]. The Journal of Biomedical Research, 2015, 29(1): 76-82. DOI: 10.7555/JBR.29.20140083
    [6]Zhixuan Zhou, Wu Chen, Ming Shen, Chao Sun, Jun Li, Ning Chen. Cone beam computed tomographic analyses of alveolar bone anatomy at the maxillary anterior region in Chinese adults[J]. The Journal of Biomedical Research, 2014, 28(6): 498-505. DOI: 10.7555/JBR.27.20130002
    [7]Jinshan Tang, Ziqiang Zhu, Tao Sui, Dechao Kong, Xiaojian Cao. Position and complications of pedicle screw insertion with or without image-navigation techniques in the thoracolumbar spine: a meta-analysis of comparative studies[J]. The Journal of Biomedical Research, 2014, 28(3): 228-239. DOI: 10.7555/JBR.28.20130159
    [8]Yang Zhou, Ouyang Ling, Li Bo. Expression and significance of lysyl oxidase-like 1 and fibulin-5 in the cardinal ligament tissue of patients with pelvic floor dysfunction[J]. The Journal of Biomedical Research, 2013, 27(1): 23-28. DOI: 10.7555/JBR.27.20110142
    [9]Sundeep?S.?Tumber, Hong?Liu. Epidural abscess after multiple lumbar punctures for labour epidural catheter placement[J]. The Journal of Biomedical Research, 2010, 24(4): 332-335. DOI: 10.1016/S1674-8301(10)60046-2
    [10]Guixia?Tang, Minjun?Ji, Haiwei?Wu, Guanling?Wu. Antigen?presenting?cells?may?be?able?to?distinguish?between?normal?and?radiated?Schistosoma?japonicum?cercaria:?an?in?vitro?observation[J]. The Journal of Biomedical Research, 2010, 24(4): 285-291. DOI: 10.1016/S1674-8301(10)60040-1